Power Supply Systems for Storage
Tanks


SunPump System 2000™
by ClearSkies,
Inc.
U.S. Patent #
5692647
| |
 | General Specifications: SunPump
System2000™
can be used to power most all 12-24 volt D.C. fuel delivery
pumps. Typical application includes photovoltaic modules which maintain a
deep cycle battery to provide operating voltage for fuel delivery pumps. A
wireless emergency fuel shut-off switch module is easily mounted anywhere
within 50' of the fuel storage tanks. A central electronics enclosure is
mounted on a steel pole mast mounted directly to fuel storage tank. Options purchased
separately include, a
wireless overfill and interstitial detection alarm system provides both
visual and audible alarm indicators. A key locking system prevents product
theft. The entire unit is uniquely designed for 100% portability and ease of
installation.
Click here to see our options. |
 | Power Source: Typical
application: 1 ea. 12 volt D.C.. 95 amp. deep cycle, valve regulated sealed
lead acid batteries. Specifically designed industrial strength batteries
retain a charge 3-10 times longer than old vented types. Approved by the FAA
& U.S. Government. Meets 14 CFR part 21, sec. 303 FAR's Meets D.O.T.
standards 49 CFR sec. 173.159, not a hazardous material. Weight 126 lbs.
13.8 volts maximum. |
 |
cell type....................... sealed lead acid-
valve regulated gas absorbed electrolyte. |
 |
safety.......................... produces < 2%
hydrogen gas |
 |
reserve minutes........... 1196 minutes based upon 5
amp draw. |
 |
construction................ rugged, sealed, puncture
resistant polypropylene case/cover. |
 |
Capacity 1 charge......... 800 to 1500 gallons
delivered @18amp draw. |
 | Solar Panel: All
panels used in the SunPump System 2000 models are anodized
aluminum framing in each panel : 35 " w x 39" l. Rated 17.5 volts 50
watts maximum power field wiring: copper only, 14awg insulated for 75Degree
C. Fire Rating: Class C complies with jpl blockV tests. All modules exceed
government specifications for ; thermal cycling, thermal shock, electrical
isolation, freezing and high humidity cycling, hail impact, field exposure,
mechanical wind and twist loading tests. 45 lbs. total panel weight. |
 | Wireless
Communications: Wireless
communication receivers and transmitters, certified by F.C.C. All
transmitters operating range, up to 50' VHF frequency bandwidth. Battery:
Transmitter, Eveready A23 type or equivalent 12 volt alkaline lighter
battery. Transmitter and Receiver: each user settable codes, prevents
product theft. Remote transmitters offer full weatherproof protection &
enclosed in pole mounted enclosure with resettable key locking switch. |
 | Physical
Specifications: |
| Panel Array & Mast/vent:
45 lbs.............35" W x 39" L |
Central Electronics Enclosure:........................ 100 lb.;
36"x36"x24" |
|
| Wireless /Shut-off switching:
................................... 4.5lb.;
7"x8"x4" |
Operating
temperature ........................ -10o to +65oCelsius
|
 | Central Electronics
Enclosure: Rust resistant weatherproof cabinet for central
electronics and battery storage . Pole mast mounted cabinet includes
isolation for central electronics communications receiver, charging circuit
module and multiple battery storage. Access panel provides for ease of
maintenance and installation. |
| Main System board: |
|
Wire terminals................................... euro-style terminals sized
for # 6 AWG wire . Secured terminal isolation, All contact points clearly
identified for simple installation. |
|
Max wire size (solid)............................. #8 AWG |
|
Min. wire size....................................... #16 AWG |
|
Terminal lug hook-up- spade/marked
|
|
Surface mount technology
|
|
Reverse polarity protected |
|
Negative Ground
|
| Charging Circuit: |
|
input voltage...................................... 30 vdc |
|
input current max.............................. 30 ADC |
|
input current minimum....................... 30 mA
|
|
charge stop voltage.......................... 14.35 vdc |
|
call wiring.............................................. copper only
|
|
operating temperature..................... -40o C. / +65oC.
|
|
electronic fuse/system safety
|
|
humidity to 100%
|
|
radiated noise<100 picowatts/Khz.
|
|
low noise rc filtered output, line noise less than 400mV pulses under 500
nanoseconds width
|
|
Electrical LCD display, 3 LED's display system charging status |
|
self consumption............................... typical 10mA |
|
typical serviceable life of relays- 10,000 cycles @ 30 amps use |
 | Fuel Vent/Tower Mast:
Solar panel pole mast provides tank venting as well as solar array mount.
62" height meets NFC for fuel venting and eliminates the need for a separate
support for the SunPump system. Also provides mounting support for the
central electronics enclosure. Entire mast and vent pole assembly engineered
for durability, high wind loading and transportability incorporating double
lock hinge system.
tank mount.......................................... standard 3"N.S.H
thread
vent pipe............................................. 3" Schedule A
steel pipe
rust resistant................................... powder coated gray finish |
|